The timegrapher NO.1000 is a precise mechanical watches test instrument, which is used for multi-testing by watch manufacturers and watch technician. This watch tester automatically calculates rate, amplitude, and beat error and display them by data in real time For the conventional beat, the watch timing tester can automatically response; for the special beat, it can manually select. Measurement position: 1-6 position. The lift angle can be set to between 30°and 70° Measuring possibilities: Rate deviation, amplitude, beat error: Rate deviation measurement: the range of deviation is± 999 sec / day, precision 1.0 sec/day. Amplitude measurement: Numerical display in degrees, resolution is1°, measuring range:100° to 360° (the lift angle can affect the amplitude, range: 30°to 70°.Under normal circumstances, the amplitude value do not exceed 330°.) Measuring position: 1 to 6 positions Supply voltage: single-phase AC 100 V~240V ± 10% two-line Working environment: 0 ℃ to 50 ℃, relative humidity: 0 to 80% RH Tips of SWANSOFT timegrapher No.1000: ⫸Scope of application: -Only for mechanical movement watches, quartz movement watches are not supported. ⫸ Model limitation: -Basic model is suitable for ordinary mechanical watches. For high-end watches (e.g. Omega Co-Axial 2500/8500), it is necessary to input movement information manually, so it is recommended to choose advanced models for testing. ⫸ Oscillation Requirements: -Make sure the watch swing angle is 220° ~ 320°. ⫸Environmental Requirements: -Stay away from high radiation or noise sources such as cell phones, chargers, TVs, stereos, computers, LED lights, ultrasonic cleaners, electromagnetic ovens, microwave ovens, etc. during the test to avoid interfering with the pickup signals. Package Content 1 * Timegrapher 1 * Timegrapher Sensor 1 * US Adapter 1 * User Manual The following are common problems with the WATCH EXPEPT Precision Mechanical Watch Tester and how to deal with them: 1. Screen is dark or no display -Check if the power connection is normal. -Check that the power indicator light is on. If not, check the power adapter and cable connections. ((If the cord is not energized, please let us know and we will replace it of charge). 2. Cannot work normally -Check that the instrument is correctly placed, avoiding direct sunlight and extreme temperature environments. -Check that the microphone is away from noise sources and properly connected to the host computer. -Try to restart the device. 3. Scattered or irregular curves -Check if the watch is placed stably on the test position. -Manually adjust the beat frequency setting to ensure it matches the watch under test. -Adjust the sensor input gain to minimize noise interference. 4. Abnormal measurement data such as rate, amplitude, beat error, etc. -Check if the watch is in normal motion, such as dry lubricant or damaged internal parts may cause abnormalities. -Recalibrate the parameter settings according to the specific model, such as the angle of lift (default 52°), measurement period (2 seconds to 60 seconds), etc. 5. Inaccurate sound analog playback -Check if the speaker is working properly. -Check that the menu/speaker keys are properly configured. Best Gift Ideas: SWANSOFT Watch timegrapher is the perfect gift for Father's Day, Birthday, Retirement, Graduation and any other special occasion. SWANSOFT Timegrapher No.1000, Multifunctional Watch Tester, Watch Timing Mach... SWANSOFT Timegrapher No.1000, Multifunctional Watch Tester, Watch Timing Mach... SWANSOFT Timegrapher No.1900, Multifunctional Watch Tester, Watch Timing Mach... SWANSOFT Timegrapher No.1900, Multifunctional Watch Tester, Watch Timing Mach... Add to Cart Add to Cart Add to Cart Add to Cart Customer Reviews 4.6 out of 5 stars 194 4.6 out of 5 stars 194 4.6 out of 5 stars 69 4.6 out of 5 stars 69 Price $158.99$158.99 $169.00$169.00 $209.99$209.99 $219.00$219.00 Item Model NO.1000 NO.1000 NO.1900 NO.1900 Feature LCD display LCD display LCD display LCD display What watch is suitable? Mechanical watches Mechanical watches Mechanical watches Mechanical watches After-service ✓ ✓ ✓ ✓ Color White Black White Black Test items The test items include daily difference, pendulum amplitude, and polarization. The measurement range of diurnal aberration is ±999 sec/day, and the accuracy is 1.0 sec/day The test items include daily difference, pendulum amplitude, and polarization. The measurement range of diurnal aberration is ±999 sec/day, and the accuracy is 1.0 sec/day The test items include daily difference, pendulum amplitude, and polarization. The measurement range of diurnal aberration is ±999 sec/day, and the accuracy is 0.1sec/day The test items include daily difference, pendulum amplitude, and polarization. The measurement range of diurnal aberration is ±999 sec/day, and the accuracy is 0.1 sec/day